Flexible segmented coverage
Cell grids support sidewall, top or wraparound placement where the selected construction and seam geometry permit.
Ice Pack · Hydrate Dry Ice Packs
A 24-cell Hydrate Ice Pack for wraparound or sidewall coolant placement in insulated food and seafood packouts. It is supplied dry as a water-activated cooling sheet and must be hydrated, drained and fully frozen before loading. Reference sheet size is 28 × 39 cm with a nominal 0 °C formulation option; confirm hydrated mass, materials and conditioning for the selected configuration.
Product Overview
The 24-cell Hydrate Ice Pack uses a segmented water-activated sheet structure for flexible coolant placement around temperature-sensitive payloads. Confirm the sheet construction, hydrated mass, cell geometry and hydration-and-freezing procedure before integrating it into an insulated packout.
Cell grids support sidewall, top or wraparound placement where the selected construction and seam geometry permit.
The sheet is hydrated at the packing site to the model-specific target mass before freezer preparation.
A controlled hydration, drainage and freezing procedure helps keep coolant mass and starting state consistent.
Confirm cell count, sheet size and hydrated mass against the available space and coolant placement in the insulated shipper.
Product Parameters
Product Specifications
Use these reference options to select a starting configuration. Final values are recorded in the product drawing and order specification before sampling or production.
| Specification | Reference data | What to confirm |
|---|---|---|
| Configuration | 24 sealed cells | Confirm cell pitch, seam width and finished count. |
| Reference sheet size | 28 × 39 cm | Confirm the selected cell count, finished sheet size and dimensional tolerances on the current drawing. |
| Reference outer options | PE/PA, PE/PET, laminated non-woven or kraft paper | Select the outer construction confirmed for the ordered model. |
| Reference nominal phase transition | 0 °C | Confirm formulation, method and tolerance. |
| Conditioning | Hydrate, drain, inspect and freeze flat | Exact settings must come from the model-specific work instruction. |
| Thermal duration | Confirm with technical sales | Validate at packout level. |
Use & Packout
Control hydrated mass, drainage, freezing and handling for the selected sheet before loading it into a validated shipping arrangement.
Match the model code, cell count, dimensions and facing construction to the selected product drawing and activation instruction.
Use clean water and stop activation at the model-specific hydrated mass or other stated acceptance criterion.
Remove excess surface water, check all cells and seams, and reject any sheet with punctures, delamination or leakage.
Freeze with adequate airflow until the complete sheet reaches the required starting state in the selected work instruction.
Place the specified sheet quantity and orientation in the documented packout, protecting it from sharp edges and excessive compression.
Complete shipping system performance
Confirm the minimum and maximum product load, coolant quantity and pre-freezing or conditioning method, insulated shipper, ambient-temperature profile for the shipping lane and transit duration in a defined complete-packout thermal test or qualification protocol.
These references explain industry qualification and transport practices. They do not certify this product or replace testing of your complete packout. Using an ISTA 7E profile alone does not constitute ISTA certification.
The 24-cell grid distributes the hydrate fill across a 28 × 39 cm sheet; alternative cell counts are available so the pack can be matched to a specific carton floor area or to a preferred frozen-pack flexibility.
Sheet length and width are produced to your carton footprint, with the cell grid laid out so the pack still freezes flat and stacks evenly in the freezer.
PE/PA and PE/PET constructions give tear and puncture resistance against carton edges, while PE laminated to non-woven provides a soft face that will not scuff printed packaging.
Supplied with a hydrate dry fill at a 0 °C transition point; the same pack construction can be built to a different transition point where the target load temperature requires it.
Branding, usage text and weight or cell-count markings can be printed directly on the pack face or on the non-woven layer.
Project Configuration
Share payload, usable internal space, temperature requirement, transit duration, route profile, order volume and presentation needs for technical and manufacturing review.
Product Documents
Available documents vary by model, material construction and coolant formulation. Ask us to confirm the files available for your quotation or sample.
Dimensions, weight or capacity, material construction, conditioning instructions and carton-packing data for the selected model.
Handling and disposal information for the selected coolant formulation, where applicable.
Product dimensions, artwork area and carton data for the selected model.
Frequently Asked Questions
Use these answers for initial selection. For ordering and packout setup, follow the specifications and instructions confirmed for your model.
A segmented format can support distributed placement and conformability, but the actual benefit depends on sheet geometry, hydrated mass and a documented packout, where available.
It is a water-activated coolant sheet supplied dry for hydration and freezer conditioning. The product-category name does not mean solid carbon dioxide, so dry-ice handling and dangerous-goods assumptions should not be applied to it.
Fold only within the approved handling limits and cut only along designated seams, if the supplier drawing permits it. Damaging a cell or seal can invalidate the packout.
Specify a payload-temperature requirement and route profile, then test the full shipper. Hold time must be established by testing the complete packout under the intended route conditions.
Quote & Sample Request
Share the information below so our team can recommend a suitable product configuration.
Selected product
We will review a standard or custom configuration after receiving your project details.
Our response will cover the selected model, available documents and sample options.