Manuel d'utilisation

Insulated Shipper Instructions

Conditionnement & Packout Manuals

View translated reference manuals for the insulated box identified as “1#” in the source manuals using refrigerant plates labeled -18°C, +5°C, or +15°C. The PDFs show the documented component set, conditioning paths and illustrated plate placement.

Document status: The public PDFs do not display a document ID, révision, effective date or approval record. Considérez-les comme des références traduites et demandez le manuel contrôlé en vigueur pour la configuration exacte du conteneur avant toute utilisation opérationnelle. L’étiquette d’une plaque ne permet pas, à elle seule, d’établir une plage de température de la charge utile ni une durée qualifiée.

Before You Condition or Pack

Do not begin with a coolant temperature alone. Start with the approved product requirement and reproduce the documented packout inputs.

  1. Confirm the target: use the product label, spécification du client, plan de sécurité alimentaire, or quality-approved temperature limits and excursion rules.
  2. Match every component: verify the exact insulated box and the 1-A, 1-B, and 1-C refrigerant plates shown in the selected PDF.
  3. Check condition: inspect each component against the approved acceptance criteria; do not use any component that fails them.
  4. Reproduce conditioning: control the conditioning environment, minimum time, physical state, and surface-temperature acceptance check.
  5. Prepare the payload: confirmer les dimensions, poids, quantité, température initiale, séparation, and any required barrier from coolant panels.
  6. Load exactly: follow the illustrated top, bas, front, rear, and side placement; do not substitute panel quantities or positions.
  7. Record and monitor: document the manual revision, start time, conditioning result, fermeture, logger identity and position, and shipment handover.
  8. Approve the lane: compare the qualified test profile with the route, indemnité de retard, saisons chaudes et froides, et processus de réception.

Manuals by Refrigerant-Plate Label

Choose by the exact shipper and plate configuration, not by label alone. The summaries on this page state what can be confirmed from each public file; utilisez le PDF pour sa mise en page illustrée et obtenez la version contrôlée en vigueur avant de préparer une expédition.

1# Insulated Box with -18°C-Labeled Refrigerant Plates

This translated reference shows one 1# box configuration and its plate-placement diagram. It does not state a qualified payload range or transport duration.

-18°C
étiquette
Panel quantity1-A x 4, 1-B x 4, 1-C x 2
Document statusTranslated reference · Revision review required
Performance scopePayload range and qualified duration not stated
Source file5 pages with one illustrated layout

Reference workflowverify against current revision

  1. Confirm the current document and match the box, plate type, quantity and payload specification.
  2. Condition and temper the plates only to the setpoint, minimum time, physical state and measurement location in the approved revision.
  3. Place two 1-A plates at the bottom and two at the top; position four 1-B and two 1-C plates as shown in the applicable diagram.
  4. Close and seal the box, position the monitor as approved, and record the conditioning result and shipment start.

1# Insulated Box with +5°C-Labeled Refrigerant Plates

This translated reference shows two conditioning paths for one 1# box configuration. The correct path depends on the approved payload and shipping profile.

+5°C
étiquette
Panel quantity1-A x 4, 1-B x 4, 1-C x 2
Document statusTranslated reference · Revision review required
Performance scopePayload range and qualified duration not stated
Source file6 pages with two illustrated layouts

Reference workflowverify against current revision

  1. Confirmez la version en vigueur du document et la procédure de mise en condition thermique approuvée pour la charge utile, route and ambient profile.
  2. Match the box and plate set, then condition and temper the plates to the approved state and measured acceptance range.
  3. Reproduce the applicable diagram using four 1-A, four 1-B and two 1-C plates; do not combine the two paths.
  4. Close and seal the box, position the monitor as approved, and record the path, conditioning result and shipment start.

1# Insulated Box with +15°C-Labeled Refrigerant Plates

This translated reference shows two conditioning paths for one 1# box configuration. It does not establish a general 15 to 25°C performance claim.

+15°C
étiquette
Panel quantity1-A x 4, 1-B x 4, 1-C x 2
Document statusTranslated reference · Revision review required
Performance scopePayload range and qualified duration not stated
Source file6 pages with two illustrated layouts

Reference workflowverify against current revision

  1. Confirmez la version en vigueur du document et la procédure de mise en condition thermique approuvée pour la charge utile, route and ambient profile.
  2. Match the box and plate set, then condition and temper the plates to the approved state and measured acceptance range.
  3. Reproduce the applicable diagram using four 1-A, four 1-B and two 1-C plates; do not combine the two paths.
  4. Close and seal the box, position the monitor as approved, and record the path, conditioning result and shipment start.

Document Control and Qualification

Confirm the current revision

Avant approbation, request the current manual, engineering drawing, refrigerant-plate specification, plate dimensions, diagramme d'emballage, and available test report for the quoted SKU.

Qualify the actual packout

Evaluate representative minimum and maximum payloads, conditionnement, positions des enregistreurs, profils ambiants chauds et froids, temps de parcours, retards, manutention, et critères d'acceptation.

Control operational changes

Review changes to the box, panels, fournisseur, charge utile, quantité, position, équipement de conditionnement, itinéraire, saison, fermeture, or monitoring plan before reuse.

WHO technical guidance treats conditioning, chargement, manutention, surveillance, and qualification as parts of a defined transport process. Voir le Bibliothèque d'orientations de distribution de l'OMS et le WHO passive-container and coolant-pack handbook. L'étiquette du produit, customer quality system, réglementation applicable, and approved qualification remain controlling.

Need the Current Manual or a Packout Review?

Share the box and refrigerant-plate model, payload temperature limits, payload mass and dimensions, durée de l'itinéraire, profil ambiant saisonnier, current document revision, and monitoring requirements. Huizhou peut identifier le document pertinent ou signaler les cas dans lesquels une revue de la configuration est nécessaire.

Retour en haut